- Diesel Generators[24]
- Rigid PCB[1]
- Water Meters[11]
- Voltage Regulators/Stabilizers[1]
- Educational Toys[1]
- Testing Equipment[9]
- Other Metal Processing Machinery[1]
- LED Backlights[1]
- Push Button Switches[1]
- LED Lamps[1]
- Industrial Lighting[1]
- Transformers[1]
- Industrial Power Supply[1]
- Uninterrupted Power Supply (UPS)[1]
- Alarm[1]
- Other Welding Equipment[1]
- Power Distribution Equipment[12]
- Nuts[6]
- Switching Power Supply[3]
- Circuit Breakers[3]
- Contact Person : Mr. Liu Gang
- Company Name : Zhejiang Aodekang Meter & Instrument Co., Ltd.
- Tel : 86-577-62725266
- Fax : 86-577-62730328
- Address : Zhejiang,Wenzhou,Aodekang Mansion,No.408, Liuweng West Road, Liushi
- Country/Region : China
- Zip : 325604
portable kwh meter test bench
Detailed Product Description
Three Phase Energy Meter Portable Test Equipment
(With Voltage source and Current Source)
1. Brief Introduction:
three-phase portable test equipment with current and voltage source is an ideal device to test all kind three-phase energy meters accuracy below 0.2, especially for testing un-installed meters on site. The equipment can generate 3-phase voltage, 3-phase current and any power factor signal, the standard meter inside the equipment is class 0.05.
The equipment is box structure, light, and easy to carry, it is very convenience to test meters on site, moreover the equipment can be used for repair meter in meter manufacture and as testing equipment in R&D institute.
2. Advantages:
a. Displays of vector diagram for analysis of the supply conditions.
b. DDS technology signal generator:
The signal generator adopts digital sine wave composing technology. The signal generator can trace the voltage phase and supply a dummy load to the tested meter by outputting adjustable current with different phase ;
c. High efficiency D-Class current amplifier and voltage amplifier:
The equipment adopts PWM power amplifier(or we called D-Class amplifier), which is high efficiency (>85%) and very low heat consumption. The amplifier has protect function ,it can avoid damage due to wrong connection or other manual operations. Current amplifier and output shifter can output different current; Voltage amplifier can output different voltage;
d. Large LCD screen display.
3. Main specification:
Power and consumption:
Power supply: 1P2W 220V ±10%, 50Hz or 60Hz;
Max. consumption: 300VA
Current source:
Output current: 3×0. 1A-3×100A
Adjusting resolution: 0.01% (min. 0.0001A)
Power factor: 0~3600; resolution: 0.10
Output frequency: 45Hz~65Hz;
Distortion(sine wave output): <0.5%
Current stability of power source during sine wave output:
0.05% (180s)
Output wave: sine wave
2-21 harmonic wave, total should be less than 40%
Odd harmonic waveform
Sub harmonic waveform
Output capacity: 50VA per phase
Voltage source:
Load: The Load can be resistor / inductive / capacitance(<4uF)
Adjusting resolution: 0.01% (min. 0.1V)
Output frequency: 45Hz~65Hz;
Distortion(sine wave output): <0.7%
Voltage stability of power source during sine wave output:
0.05% (180s)
Output wave: sine wave
2-21 harmonic wave, total should be less than 40%
Odd harmonic waveform
Sub harmonic waveform
Output capacity: 50VA per phase
Build in Reference Meter:
Voltage range: 3×30V-3×300V (AC)
Current range: 3×0.001A-3×100A (20/100A current clip) (AC)
Accuracy:
Active power 0.05% (PF>0.5)
Reactive power 0.1% (PF>0.5)
Warm up time: < 2 minutes
Build in Error Calculator:
Impulse of tested meter could be: TTL / OC / Optical head
Max. frequency of impulse could be: 200Hz
Error display range: 0.001%-99.99%